2017-11-10 |
TEX map commented out. Added: pulse quality check, use of different ratios (average, nstrip average, single sector ratio) and use of integral or height of pulse shape to estimate Vdepl(the height has probably some mistakes e.g. takes ratio obtained for integral mode).
Michele Atzeni
committed
on 10 Nov 2017
|
---|---|
Fill: 1616, uses integral of pulse shape but no request on the quality of pulseFit like in a normal voltaFit
Michele Atzeni
committed
on 10 Nov 2017
|
|
we can now have different ratios for different nstrips
Michele Atzeni
committed
on 10 Nov 2017
|
|
Resetted the pulseFit to a previous version. It was added a fit with 3rd order poly to evaluate the second derivative in the points and determine if the pulse shape is healty
Michele Atzeni
committed
on 10 Nov 2017
|
|
2017-09-17 |
Merge branch 'master' of ssh://git.physik.uzh.ch:8443/egraveri/STAging
Michele Atzeni
committed
on 17 Sep 2017
|
r-10 feature in temporary files explained
Michele Atzeni
committed
on 17 Sep 2017
|
|
2017-09-07 |
Merge branch 'master' of ssh://git.physik.uzh.ch:8443/egraveri/STAging
Elena Graverini
committed
on 7 Sep 2017
|
[macros/CCEScan/batch] Update batch scripts to hadd the landau fit outputs and run the pulse and voltage fits
Elena Graverini
committed
on 7 Sep 2017
|
|
2017-09-06 |
removed the rescaling that allowed to use the integral instead of the maximum of the pulse shape
Michele Atzeni
committed
on 6 Sep 2017
|
USE OF MAXIMUM of pulse shape instead of INTEGRAL, only POLY3 is used.
Michele Atzeni
committed
on 6 Sep 2017
|
|
Setting back CCEScan.root as file to use
Michele Atzeni
committed
on 6 Sep 2017
|
|
Percentage used to estimate depletion voltage is common for all sectors: r = (95 +/- 2) %
Michele Atzeni
committed
on 6 Sep 2017
|
|
2017-09-05 |
Switched back to the correct file as input CCEScan.root, not CCEScan_TEST.root
Michele Atzeni
committed
on 5 Sep 2017
|
Switched back to the correct file as input CCEScan.root, not CCEScan_TEST.root
Michele Atzeni
committed
on 5 Sep 2017
|
|
The data point is ignored if a systematic error is not present (sys set to -999)
Michele Atzeni
committed
on 5 Sep 2017
|
|
A file called noSystematic_val#.txt cointains all the steps were no systematic erros was found for the integral of the pulse shape
Michele Atzeni
committed
on 5 Sep 2017
|
|
Comments on the systematics
Michele Atzeni
committed
on 5 Sep 2017
|
|
2017-09-04 |
Trying to fix merging conflict
Michele Atzeni
committed
on 4 Sep 2017
|
restoring elena's version
Michele Atzeni
committed
on 4 Sep 2017
|
|
restoring elena's version
Michele Atzeni
committed
on 4 Sep 2017
|
|
Putting back some fills
Michele Atzeni
committed
on 4 Sep 2017
|
|
2017-09-03 |
Introduces systematic uncertainty on CCE, however this is merged with the statistical uncertainty to avoid a huge modification of the code
Michele Atzeni
committed
on 3 Sep 2017
|
increased dimension of saved vector (11->12) due to introduction of systematic error on equivalent collected charge
Michele Atzeni
committed
on 3 Sep 2017
|
|
Added a fit of pulse shape with poly on degree 3, 4, 5 to estimate systematic error on integral of pulse
Michele Atzeni
committed
on 3 Sep 2017
|
|
2017-09-01 |
[macros/CCEScan/batch] Update environment, use all fills
Elena Graverini
committed
on 1 Sep 2017
|
[macros/CCEScan] Add latest fills
Elena Graverini
committed
on 1 Sep 2017
|
|
[macros/CCEScan/batch] Update env variables
Elena Graverini
committed
on 1 Sep 2017
|
|
[macros/CCEScan/batch] Update to SLURM
Elena Graverini
committed
on 1 Sep 2017
|
|
[macros/CCEScan] Remove unused code
Elena Graverini
committed
on 1 Sep 2017
|
|
Merge branch 'master' of ssh://git.physik.uzh.ch:8443/egraveri/STAging
Elena Graverini
committed
on 1 Sep 2017
|